From eb3940fab4e6469c8ede41f03037427dda4d41c5 Mon Sep 17 00:00:00 2001 From: kliment Date: Sun, 1 May 2011 16:31:46 +0200 Subject: Added watchdog aand minimal temp for greater safety in the case of a disconnected thermistor --- Tonokip_Firmware/configuration.h | 7 +++++++ 1 file changed, 7 insertions(+) (limited to 'Tonokip_Firmware/configuration.h') diff --git a/Tonokip_Firmware/configuration.h b/Tonokip_Firmware/configuration.h index 019a9fd..f97ad6b 100644 --- a/Tonokip_Firmware/configuration.h +++ b/Tonokip_Firmware/configuration.h @@ -37,6 +37,13 @@ float min_constant_speed_units = 2; // the minimum units of an accelerated move //#define SMOOTHING 1 //#define SMOOTHFACTOR 16 //best to use a power of two here - determines how many values are averaged together by the smoothing algorithm +//Experimental watchdog and minimal temp +//The watchdog waits for the watchperiod in milliseconds whenever an M104 or M109 increases the target temperature +//If the temperature has not increased at the end of that period, the target temperature is set to zero. It can be reset with another M104/M109 +//#define WATCHPERIOD 5000 //5 seconds +//The minimal temperature defines the temperature below which the heater will not be enabled +//#define MINTEMP + // Select one of these only to define how the nozzle temp is read. #define HEATER_USES_THERMISTOR //#define HEATER_USES_AD595 -- cgit v1.2.1